Symptoms
The gas main burner would turn on and the fan limit switch torsion switch would rapidly rotate turning on the air handler fan motor then it would appear that the heat exchanger would cool down as you would observe the fan limit switch rotate quickly towards the cool side. This would end up turning off the motor. The air handler fan motor would cycle on and off in short cycles.
Fix
I bought a new fan limit switch and replaced the existing unit. Now the furnace acts as I would have expected it to. My unit uses the 8 inch long Honeywell part number: L4064B 2236 L4064
Notes
The fan limit swich bimetallic torsion bar must have failed in my
Fan Limit Switch
Control Circuit Diagram:
Sunbeam Seneca SL-XXX
Research Links
How the Pilot Light Safety System Works